Breast SOGs: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
===Mammography=== | ===Mammography=== | ||
[[ | |||
[[File:Imaging SOP Mammo Indications and Views 2022.14.06 Final.pdf|thumb|Mammo Indications and Views 2022]] | |||
* <30 y/o or pregnant: ultrasound first, mammo only if needed | * <30 y/o or pregnant: ultrasound first, mammo only if needed | ||
Line 25: | Line 26: | ||
===Other=== | ===Other=== | ||
* [[:File:|Outreach Policies]] | * [[:File:SOG_Outreach.doc|Outreach Policies]] | ||
* [[:File:|Suboptimal Image Quality]] | * [[:File:SOG_Supoptimal_Imaging_Quality_2017.pdf|Suboptimal Image Quality]] | ||
* [[:File:|Patient Result Notification]] | * [[:File:SOG_Patient_Result_Notification.docx|Patient Result Notification]] | ||
* [[:File:|Scheduling Patients with Implants]] | * [[:File:SOG_scheduling_of_pts_with_implants.docx|Scheduling Patients with Implants]] |
Latest revision as of 22:00, 12 December 2022
Mammography
File:Imaging SOP Mammo Indications and Views 2022.14.06 Final.pdf
- <30 y/o or pregnant: ultrasound first, mammo only if needed
- <6 mo since last mammo: spot/mag CC, spot/mag MLO, ML
- >= 6 mo: as above but add routine CC, MLO
- 1 view findings: rolled CCs, ML, spot in view where seen
- No post-bx mammo required for age <30 and either no prior mammo, or clip clearly seen with ultrasound
ACR Practice Guideline for Mammography
Ultrasound
Breast Ultrasound Axillary Ultrasound
- Performed (ipsilateral) with breast u/s for BI-RADS 4c or 5 lesions AND lesion is >=2cm
- Performed (ipsilateral) for new diagnosis of invasive breast cancer and specifically requested
- If multiple abnormal nodes, number them from inferior to superior
- Radiologist fills out specimen pathology sheet